军事知识服务平台
电磁超声测井换能器仿真模拟分析
Simulation and Analysis of Electromagnetic Ultrasonic Logging Transducer
摘要 超声测井技术采用的压电超声换能器工作时需依靠油水等介质实现声场耦合,对耦合介质的强依赖性使其难以适配储气井、充气井、干井等无水特殊井筒环境,在重钻井液、低密度水泥等复杂固井工况下还存在胶结缺陷识别灵敏度不足的问题,制约了传统超声测井技术在固井质量评价中的应用.电磁超声传感技术无需耦合介质,能够直接在金属套管导体内部激发与接收超声波,具备非接触测量、耐温耐压性能优异、可激发多种导波模态等突出优势,是解决无水井固井检测难题的重要技术方向,但换能器能量转换效率偏低仍是限制其工程落地的主要瓶颈.该研究面向套管固井胶结质量评价实际需求,构建电磁学和力学多物理场耦合有限元仿真模型,以套管周向水平剪切波为研究对象,系统探究激励频率、提离距离 2 个关键参数对超声导波传播特性的调控规律,分析水泥密度、水泥环厚度等固井物性参数对接收信号的干扰机理,优化接收换能器环向布置方案,并通过室内套管物理实验对仿真结论开展对比验证.研究结果表明:采用电磁超声传感技术激励 SH0 模式波时,接收换能器环向最优布置区间为距离激励换能器 60°~120°;该方法可有效评价第Ⅰ、第Ⅱ界面水泥胶结质量,但受剪切波传播机理限制,无法判别流体微环所处的界面位置;水泥密度升高会加剧导波衰减,水泥环厚度与导波波长的匹配关系直接影响波形畸变程度,可依据接收波形特征反演水泥密度,同时需要规避水泥厚度变化引入的杂波干扰;换能器能量转换效率随激励频率升高呈现先上升后下降的变化趋势,存在最优工作频率;随磁铁与线圈到套管的提离距离增大,耦合效率持续衰减,0.2~1.0 mm 为提离距离最优工作区间,可通过机械限位、弹性扶正适配与信号反馈机制实现井下工程精准控制.有限元仿真与室内实验一致性较好,相关结论可为电磁超声测井换能器参数优化、仪器结构设计以及充气类复杂井况固井质量评价的工程化应用提供关键理论依据与技术参考.
Abstract:
The piezoelectric ultrasonic transducer employed in conventional ultrasonic logging relies critically on liquid coupling media,such as oil or water,to achieve effective acoustic field transmission.This stringent dependence on a coupling medium severely limits its applicability in waterless wellbore environments,including gas storage wells,gas injection wells,and dry wells.Moreover,under complex cementing conditions,such as those involving heavy drilling mud or low-density cement,the transducer exhibits insufficient sensitivity for detecting cementing defects,thereby constraining the reliability of traditional ultrasonic logging in cement bond evaluation.In contrast,electromagnetic acoustic transducer(EMAT)offers a contactless alternative:it directly generates and detects ultrasonic waves within metallic casing walls without requiring any coupling medium.EMAT thus provides distinct advantages,including non-contact operation,robust performance under extreme temperature and pressure conditions,and the capability to selectively excite multiple ultrasonic wave modes,making it a promising solution for cement bond assessment in waterless wells.However,its practical deployment remains hindered primarily by the inherently low energy conversion efficiency of current EMAT transducers.To address this challenge and meet the operational requirements of casing-cement-formation interface integrity evaluation,this study establishes a multi-physics finite element model coupling electromagnetic and elastodynamic fields.Focusing on the circumferential horizontal shear wave propagating along the casing wall,we systematically investigate the influence of two pivotal parameters,excitation frequency and lift-off distance,on ultrasonic wave propagation characteristics.Furthermore,we analyze how key cementing physical parameters,including cement density and cement sheath thickness,affect the received signal,optimize the circumferential angular placement of the receiving transducer array,and validate simulation findings through controlled laboratory-scale casing experiments.Results indicate that,when exciting the SH0 mode via EMAT,the optimal circumferential angular separation between the excitation and reception transducers lies between 60° and 120°.This configuration enables effective evaluation of bonding quality at both the casing-cement and cement-formation interfaces;however,due to fundamental limitations inherent to shear wave propagation physics,precise localization of micro-annular fluid layers remains unattainable.Increased cement density intensifies ultrasonic attenuation,while the interplay between cement sheath thickness and wavelength governs waveform distortion severity.Cement density can be quantitatively inverted from characteristics of the received waveform—provided interference from spurious waves induced by thickness variations is mitigated.Energy conversion efficiency exhibits a unimodal dependence on excitation frequency,peaking at an optimal value;meanwhile,lift-off distance shows monotonic degradation in coupling efficiency with increasing separation,with an experimentally validated optimal range of 0.2~1.0 mm.Practical downhole implementation of this tolerance can be achieved via mechanical stops,elastically adaptive alignment mechanisms,and real-time signal feedback control.Excellent agreement between finite element simulation predictions and experimental observations confirms the model's fidelity.These findings provide a rigorous theoretical foundation and actionable technical guidance for optimizing EMAT transducer design parameters,instrument structural configuration,and field deployment strategies,particularly in challenging well environments such as gas injection wells.
刊 名 测井技术 ISTIC
年,卷(期): 2026, 50(5)
分类号: P631.84
机标分类号: U448.27 TP391.9 TU311.3
在线出版日期: 2026年11月9日
基金项目: U21B2064:国家自然科学基金ZR2025MS541:山东省自然科学基金,