一起特高压输电线路圆柱头悬式瓷绝缘子劣化原因分析
Degradation Causes for Cylindrical Head Suspension Porcelain Insulators on UHV Transmission Lines
摘要
使用红外检测技术发现了某特高压交流输电线路圆柱头悬式瓷绝缘子发生异常发热现象,这一发现对于及时诊断和分析特高压圆柱头悬式瓷绝缘子劣化具有重要意义.为了研究劣化机理,分别通过绝缘电阻试验、工频击穿电压试验、抽样试验、瓷件解剖试验、X射线衍射试验和扫描电镜试验,全面评估了劣化样品的电气、机械和材料性能.结果表明,瓷件头部存在微裂纹及水泥胶装层存在大量气孔是造成本次瓷绝缘子劣化的主要原因.本研究不仅为瓷绝缘子的失效分析提供了科学依据,也为制定有效的预防措施和改进策略提供了指导,对于保障特高压输电线路的安全运行具有重要的实际应用价值.
The use of infrared detection technology revealed the abnormal heating phenomena in cylindri-cal head suspension porcelain insulators of a certain ultra-high voltage(UHV)AC transmission line,which is of significant importance for timely diagnosis and analysis of the degradation of UHV cylindrical head suspension porcelain insulators.To investigate the mechanism of degradation,a comprehensive as-sessment of the electrical,mechanical,and material properties of the degraded samples were conducted through insulation resistance tests,power frequency breakdown voltage tests,sampling tests,dissection tests of porcelain pieces,X-ray diffraction tests,and scanning electron microscope(SEM)tests.The results indicated that the presence of micro-cracks in the porcelain head and a large number of air bub-bles in the cement gluing layer were the main causes of the degradation of the porcelain insulator in this instance.A scientific basis for the failure analysis of porcelain insulators is provided in this study,and guidance is also offered for formulating effective preventive measures and improvement strategies.It is of great practical value to guarantee the safe operation of UHV transmission lines.