DC/DC变换器Hiccup模式短路保护电路的设计
Design of a Hiccup-mode Short-circuit Protection Circuit for DC/DC Converters
摘要 针对DC/DC变换器在负载短路时系统功耗急剧上升,以及传统限流保护方式恢复慢、易误触发等问题,本文基于0.18 μm SK Hynix工艺,设计了一款用于Buck型DC/DC变换器打嗝(Hiccup)模式短路保护电路.首先,电路通过时钟脉冲计数实现对短路时长的量化检测,并在过流阶段引入延迟触发机制,有效降低误触发概率;同时采用全数字逻辑控制,确保短路解除后系统能够在毫秒级时间内自动重启.该电路具备显著降低短路功耗、快速恢复响应且无电压过冲的优良特性.最后,通过流片测试结果表明,在输入电压12 V、带载1 A的条件下,发生负载短路时系统工作频率降至正常时的1/102.56,短路期间平均功耗仅为372.9 mW,极大缓解了因大电流输出导致的能量浪费,短路解除后输出恢复时间仅为1 ms.
Abstract:
Aiming at the issues of sharp increase in system power consumption under load short-circuit conditions in DC/DC converters,as well as the slow recovery and susceptibility to false triggering in traditional current-limiting pro-tection methods,a Hiccup-mode short-circuit protection circuit is presented which is designed for Buck DC/DC con-verters based on a 0.18 μm SK Hynix process.Firstly,the circuit achieves quantitative detection of short-circuit du-ration through clock pulse counting and introduces a delayed triggering mechanism during the overcurrent phase,ef-fectively reducing the probability of false triggering.Meanwhile,fully digital logic control is adopted to ensure that the system can automatically restart within milliseconds after the short-circuit is eliminated.The circuit exhibits excellent characteristics including significantly reduced short-circuit power consumption,fast recovery response,and absence of voltage overshoot.Finally,chip testing results demonstrate that under an input voltage of 12 V and a load current of 1 A,the system operating frequency drops to 1/102.56 of the normal value when a load short-circuit occurs.The av-erage power consumption during the short-circuit period is only 372.9 mW,greatly alleviating energy waste caused by high-current output.The output recovery time after short-circuit elimination is merely 1 ms.
刊 名 电力电子技术 ISTIC
年,卷(期): 2026, 60(10)
分类号: TM46
机标分类号: TN402 TN247 TN014
在线出版日期: 2026年10月26日