Design experiment and simulation optimization of PandaX-xT large cooling power recovery system
摘要
研究提出基于四氟化碳(R14)工质的大冷量回收系统,利用R14与氙沸点温区匹配的特性,使R14在再沸器冷凝放热后经节流,在液氙冷箱蒸发吸热以实现氙气液化与冷量回收,确保精馏系统稳定运行.为验证可行性,设计以酒精模拟低温环境的实验系统,通过液氮冷却与电加热负荷对冲测量系统制冷量.实验表明,在模拟再沸器与冷箱分别稳定于199 K与176 K时,系统制冷量达17.88 kW,效率为77.4%.基于Aspen Hysys进行流程模拟与优化,实验与模拟误差小于2.52%,通过参数敏感性分析获得最佳工况组合,理论效率提升至93.07%.该系统的研发使PandaX-xT精馏提纯流量可达855.9 kg/h(液氙5 L/min),同时摆脱对液氮和大型制冷机的依赖.
This study proposes a large cooling capacity recovery system based on tetrafluoromethane(R14).By utilizing the matching boiling-point temperature ranges of R14 and xenon,R14 condenses and releases heat in the reboiler,then passes through a throttling valve,and evaporates to absorb heat in the liquid xenon cryostat to liquefy xenon gas and recover cooling ca-pacity,thereby ensuring stable operation of the distillation system.To verify the feasibility,an experimental system using ethanol to simulate the low-temperature environment is designed.The cooling capacity is measured by balancing liquid nitrogen cooling and electrical heating loads in the simulated reboiler and cryostat.Experimental results show that when the simulated reboiler and cryostat are stabilized at 199 K and 176 K,respectively,the system achieves a cooling capacity of 17.88 kW with an efficiency of 77.4%.Based on Aspen Hysys,process simulation and optimization are performed,with a deviation between simulation and experiment of less than 2.52%.Through parameter sensitivity analysis,the optimal combination of operating conditions is ob-tained,and the theoretical efficiency is improved to 93.07%.The development of this system enables the distillation purification flow rate of PandaX-xT to reach 855.9 kg/h(liquid xenon 5 L/min),while eliminating the dependence on liquid nitrogen and large-scale refrigerators.