受限空间内阵列射流强化管外传热性能研究
Research on external tube heat transfer performance enhanced by array jet within a confined space
摘要
针对传统管壳式换热器壳程传热效率偏低、易振动和存在流动死区等弊端,提出了一种管外阵列射流冲击强化传热方式.以套管式换热器为载体,通过数值模拟研究了该强化方式在受限空间内的传热强化特性,系统分析了射流角度、分布管数量、射流速度等关键参数对传热性能和流动阻力的影响规律.结果表明:管外阵列射流可显著提高管外传热系数,在壳程流量相同情况下平均努塞尔数比传统套管式换热器提升76%;换热管周向布置的分布管数量(N=4)时综合传热因子最优;逆向倾斜射流(α=105°)传热效果最好(Nu相比于传统套管式换热器提升了 95.20%),顺向倾斜射流(α=45°)综合强化性能最佳.
To address the inherent drawbacks of conventional shell-and-tube heat exchangers,such as low shell-side heat transfer efficiency,susceptibility to flow-induced vibration,and the presence of flow dead zones,an outer-tube array jet impingement heat transfer enhancement method is proposed.Using a double-pipe heat exchanger as the geometric model,nu-merical simulations are conducted to investigate the heat transfer enhancement characteristics of the proposed method within a confined space.The effects of key parameters,including jet angle,number of distribution tubes,and jet velocity,on heat trans-fer performance and flow resistance are systematically analyzed.The results show that the outer-tube array jet impingement sig-nificantly improves the shell-side heat transfer coefficient.Under the same shell-side flow rate,the average Nusselt number is increased by 76%compared to that of the conventional double-pipe heat exchanger.The optimal comprehensive heat transfer factor is achieved when four distribution tubes are circumferentially arranged around the heat exchange tube(N=4).A reverse inclined jet(α=105°)yields the highest heat transfer enhancement,with the Nusselt number increased by 95.20%relative to the conventional design,while a forward inclined jet(α=45°)exhibits the best overall performance.This study provides a theo-retical basis for the design of high-efficiency compact heat exchangers.
年,卷(期):
2026, 54(7)
分类号:
TK172
机标分类号:
TK124
TB657.5
TQ051.5
在线出版日期:
2026年8月20日
基金项目:
JYTMS20231487:辽宁省教育厅基本科研面上项目,