军事知识服务平台
超临界机组再热器前抽汽供热能力及特性研究
Study on the Heat-supply Capacity and Characteristics of Steam Drawn Upstream of the Reheater in Supercritical Units
摘要 针对某660 MW 超临界机组外供工业用汽所面临的供热安全边界不清的现实问题,本文结合现场试验与热力仿真分析了机组再热器前抽汽供热的能力及特性.首先,提出了一套系统化试验方案并依次开展了最小干态负荷、50%BRL(锅炉额定出力)、75%BRL、100%BRL 等四种典型工况测试,试验结果表明:该机组在不同负荷工况下再热器前可抽汽量约占锅炉蒸发量的12%,最大具备外供工业供汽250 t/h 能力.随后,构建了汽轮机-锅炉-供热整体热力仿真模型并分析了机组理论供热能力及主要影响参数,分析了锅炉风量、主蒸汽温度、再热器减温水流量等3 类运行调整参数对抽汽供热能力的影响,仿真结果显示:采取"主汽微降温+适当减少风煤比"的方案可显著提升机组再热器前抽汽供热能力.
Abstract:
This paper tackles the practical issue of unclear heat-supply safety boundaries when a 660 MW ultra-supercritical unit provides industrial steam.By combining on-site experiments with thermo-dynamic simulations,the extraction capability and characteristics of steam drawn upstream of the reheater were analyzed.First,a systematic test protocol was developed and executed at four representative operat-ing points:minimum dry-load,50%BRL,75%BRL,and 100%BRL.Test results show that under all loads the extractable steam upstream of the reheater amounts to approximately 12%of the boiler's e-vaporation rate,enabling up to 250 t/h of external industrial steam supply.Next,an integrated turbine-boiler-heating simulation model was built to evaluate the unit's theoretical heat-supply capacity and i-dentify key influencing parameters.Parametric studies of boiler air flow,main-steam temperature,and reheater spray-water flow revealed that a strategy combining a slight reduction in main-steam tempera-ture with a moderate decrease in the air-coal ratio can significantly enhance the unit's pre-reheater steam-extraction heat-supply capacity.
刊 名 节能技术 ISTIC
年,卷(期): 2026, 44(4)
分类号: TK018
机标分类号: TK261 TM621 TK323
在线出版日期: 2026年9月20日
基金项目: NDFD/FWHT-2023-207:北京京能电力股份有限公司科技项目,