上海某烟厂基于数据分析的制冷系统节能优化研究
Research on Energy Efficiency Optimization of a Tobacco Factory Refrigeration System in Shanghai based on Data Analysis
摘要
为提升上海某烟厂制冷系统能效,本研究基于全年8 760 h 气象与负荷数据,构建数字孪生仿真平台,重点开发并验证冷机出水温度优化算法.通过冷机变水温调节策略动态设定冷冻水温度,结合负荷分配与开机组合优化,仿真结果表明系统全年能效比(EER)从4.80 提升至4.95(节能率3.08%).关键创新在于现场闭环验证:依托高效机房平台,在 5 400 kW 与 7 000 kW 典型负荷工况下对算法进行实测.结果显示,优化后系统 EER 分别提升 19.60%(4.10→5.10)和15.42%(4.77→5.12),证实数据仿真驱动的动态水温控制可显著提升工业制冷系统能效.
To improve the energy efficiency of the refrigeration system at a tobacco factory in Shanghai,this study utilized full-year meteorological and load data(8 760 hours)to construct a digital twin simu-lation platform,with a focus on developing and validating a chilled water temperature optimization algo-rithm.A dynamic chilled water temperature control strategy was implemented based on variable water temperature regulation and integrated with load distribution and chiller combination optimization.Simula-tion results showed an increase in the system's annual Energy Efficiency Ratio(EER)from 4.80 to 4.95,corresponding to an energy-saving rate of 3.08%.The key innovation lies in on-site closed-loop verification:relying on a high-efficiency machine room platform,the algorithm was tested under typical load conditions of 5 400 kW and 7 000 kW.The results demonstrated that the system's EER im-proved by 19.60%(from 4.10 to 5.10)and 15.42%(from 4.77 to 5.12)respectively after optimiza-tion.This confirms that data-driven,dynamic water temperature control can significantly enhance the energy performance of industrial refrigeration systems.
年,卷(期):
2026, 44(4)
分类号:
TK018
机标分类号:
TU85
TP311.52
U268.6
在线出版日期:
2026年9月20日