含银创面敷料中银含量及其均匀性的研究
Study on silver content and its distribution uniformity in silver-containing wound dressing
摘要
为建立含银创面敷料中银含量及其分布均匀性的评价方法,采用微波消解⁃电感耦合等离子体发射光谱法(ICP⁃OES)对敷料中的银含量进行定量测定,并综合运用相对标准偏差法、极差法、含量均匀度检查法及扫描电子显微镜⁃能谱分析法(SEM⁃EDS)进行统计分析.结果表明:相对标准偏差法操作便捷、结果可靠,能有效反映银含量的分布均匀程度,相较于极差法和含量均匀度检查法具有更优的适用性.推荐将相对标准偏差法作为银含量均匀性评价的常规方法,为企业质量控制、监管审评及行业标准制定提供数据支持与技术参考.
To establish an evaluation method for silver content and its distribution uniformity in silver-containing wound dressings,the silver content was quantitatively determined using microwave digestion-inductively coupled plasma optical emission spectrometry(ICP-OES).Statistical analysis was conducted by integrating the relative standard deviation method,range method,content uniformity test and scanning electron microscopy-energy dispersive spectroscopy(SEM-EDS).Results showed that the relative standard deviation method was convenient to operate,the results were reliable,and the distribution uniformity of silver content could be effectively reflected.Compared with the range method and content uniformity test,it demonstrated superior applicability.The relative standard deviation method was recommended as a routine approach for evaluating silver content uniformity,providing data support and technical reference for quality control in manufacturing,regulatory review and industry standard development.
年,卷(期):
2026, 54(10)
分类号:
TS197
R318
机标分类号:
O657.31
R927.2
R284
在线出版日期:
2026年10月16日
基金项目:
2022YFC2409704:国家重点研发计划QN202507:山东省医疗器械和药品包装检验研究院科研课题ZX201906:山东省医疗器械和药品包装检验研究院科研课题,