Airflow characteristics and water hammer elimination effect of staged exhaust valve
摘要
为提高长距离输水的安全性,设计了一种分级排气式空气阀,其结构主要包括阀体、浮体、缓冲板、管轴等,具有分级排气和负压吸气的功能,利用空气阀性能检测装置试验与数值模拟相结合的方法,研究了不同孔口尺寸缓冲板的空气阀进排气特性,计算了输水工程与该空气阀相应的停泵水锤过程.研究结果表明:空气阀在管道内相对压差 0~4 kPa 时大量排气,可减少充水能耗;大于4 kPa 时缓冲板起跳,由大量排气转为高压低速排气,缓冲板孔口尺寸44.5 mm 时,排气量由大量排气的0.883 kg/s 下降为 0.097 kg/s,可消减管道水力过渡期间的压力波动;管道运行期间微量排气,排出积存气体避免气阻;管道出现负压时,空气阀打开,向管道内快速补气.同时绘制出空气阀的进排气性能曲线;对比无空气阀和缓冲板孔口尺寸为 44.5,56.5,59.5,62.5 mm 的空气阀对管路停泵事故的防护效果,相对于无防护工况,不同缓冲板孔口尺寸时,管线最大压力包络线极值分别为 105.37,94.15,91.64,107.93,130.40 m,其中缓冲板孔口尺寸为 59.5 mm 的空气阀管道最大压力包络线极值最小.该空气阀可缓解输水管道水锤、负压、气阻等问题,为未来空气阀产品的设计提供了一定的参考.
To improve the safety of long-distance water conveyance,a staged exhaust air valve which mainly consists of a valve body,floating body,buffer plate,and pipe shaft was designed.It has the function of staged exhaust and negative pressure air intake.The intake and exhaust characteristics of the air valve with different buffer plates orifice sizes were studied by means of the combination of air valve performance detection device test and numerical simulation,and the water hammer process of the water conveyance project as well as the corresponding pump-stopping water hammer process of the air valve were calculated.The research results show that when the air valve exhausts a large amount of air at a relative pressure of 0-4 kPa in the pipeline,it can reduce the energy consumption for water filling.When the pressure exceeds 4 kPa,the buffer plate will start to release pressure,switching from large-volume exhaust to high-pressure,low-speed exhaust.When the orifice size of the buffer plate is 44.5 mm,the exhaust volume reduces from 0.883 kg/s during large-volume exhaust to 0.097 kg/s,which can reduce pressure fluctuations during the hydraulic transition of the pipeline.During the opera-tion of the pipeline,a small amount of exhaust gas is discharged to expel accumulated gas to avoid air resistance.When negative pressure occurs in the pipeline,the air valve opens to quickly replenish the pipeline with gas,and the air valve′s intake and exhaust performance curves are plotted.Comparing the protective effects of no air valve and air valves with buffer plate orifice sizes of 44.5,56.5,59.5,and 62.5 mm on pipeline pump-stoppage accidents,relative to the unprotected condition,the extreme values of the maximum pressure envelope along the pipeline for different buffer plate orifice sizes are 105.37,94.15,91.64,107.93,and 130.40 m,respectively.Among them,the air valve with a buffer plate orifice size of 59.5 mm has the smallest extreme value of the maximum pressure envelope along the pipeline.