军事知识服务平台
硫酸氢铵黏附型飞灰颗粒在空气预热器蓄热板表面沉积特性研究
Deposition behavior of adhesive ammonium bisulfate fly ash particles on regenerative plates of an air preheater
摘要 [目的]火电机组深度调峰使低负荷运行成为常态,导致空气预热器(空预器)内烟气温度显著降低、硫酸氢铵(ammonium bisulfate,ABS)沉积加剧及冷端受热面积灰堵塞严重且缺乏有效解决途径的问题.本文旨在深入探究并观测 ABS 在低负荷工况下对飞灰的黏附与沉积特性.[方法]通过改进传统的颗粒弹性模型,构建了新的沉积-剥离模型.利用该模型系统研究了 ABS 黏附型颗粒在空预器蓄热板上的沉积特性,并模拟探究了机组负荷变化对内部温度场、压力场及颗粒沉积规律的具体影响.[结果]结果发现,相较于传统模型,新的沉积-剥离模型能更好地观测颗粒在空预器中的沉积现象.ABS 黏附型颗粒在蓄热板上的沉积量随时间逐渐增加,呈现"波动上升"的趋势.在相同工况下,1~70 μm小粒径颗粒的沉积量是直径 180~200 μm 颗粒的 64 倍.负荷降低导致温度场及压力场变化,负荷每下降 10%,烟气整体温度下降约 7.7 K,进出口压差增大约 8.12 Pa.[结论]火电机组低负荷运行会显著加剧空预器冷凝受热面的积灰问题.本研究揭示的沉积规律与温压场变化特征,为解释空预器频繁堵塞的机理以及在工程中实施精确吹灰提供了重要理论依据.
Abstract:
[Objective]In the current energy landscape,the implementation of deep peak shaving in coal-fired thermal power units has transitioned low-load operation from a transient state to a long-term operational norm.This shift poses a significant technical challenge:the flue gas temperature within the rotary air preheater frequently drops below the acid dew point,leading to the intensive formation and condensation of ammonium bisulfates(ABS).The presence of ABS,characterized by its high viscosity and corrosive nature,significantly exacerbates the adhesion of fly ash,resulting in severe blockage and fouling of the heat transfer surfaces at the cold end.Despite its prevalence,the industry currently lacks an effective and systematic solution to mitigate this fouling.Therefore,this study aims to provide an in-depth exploration and microscopic observation of the adhesion and deposition characteristics of ABS-coated fly ash particles under varying low-load operational parameters.[Methods]To accurately capture the complex interaction between particles and the heating elements,this research refined the conventional particle elasticity theories by incorporating the cohesive energy effects of liquid-bridge forces.A sophisticated and novel"deposition-detachment"mathematical model was constructed to simulate the dynamic equilibrium of particle capture.Utilizing this advanced model,the study systematically investigated the deposition kinetics of ABS-adherent fly ash on the corrugated regenerative plates of the air preheater.Furthermore,through high-fidelity numerical simulations,the research quantitatively explored the sensitivity of the internal temperature distribution,localized pressure fields,and the spatio-temporal particle deposition trajectories to fluctuations in the boiler's generation load.[Results]The findings indicate that the proposed deposition-detachment model provides superior observational accuracy regarding particle deposition within the air preheater compared to conventional models.The accumulation of ABS-adherent particles on the regenerative plates demonstrates a progressive increase over time,characterized by a"fluctuating upward"trend.Under identical operating conditions,the deposition volume of small-diameter particles(ranging from 1 μm to 70 μm)was found to be 64 times greater than that of larger particles(180~200 μm),highlighting the sensitivity of fine particulate matter to ABS-induced adhesion.Moreover,the reduction in unit load triggers significant shifts in the thermal and hydraulic fields;for every 10%decrease in load,the overall flue gas temperature drops by approximately 7.7 K,while the pressure differential between the inlet and outlet increases by roughly 8.12 Pa.[Conclusion]Low-load operation of thermal power units significantly intensifies the ash fouling problem on the cold-end heating surfaces of air preheaters.The deposition regularities and the evolution of temperature and pressure fields revealed in this study provide a critical theoretical foundation for elucidating the mechanisms behind frequent air preheater blockages.Furthermore,these insights offer essential technical guidance for implementing precision soot-blowing operations in industrial engineering applications.
刊 名 热力发电 ISTICPKU
年,卷(期): 2026, 55(9)
机标分类号: TK229.66 X705 TM621.2
在线出版日期: 2026年10月23日