军事知识服务平台
基于室内点烧试验的红松不同密度与冠层间距下双冠层树冠火水平蔓延规律
Horizontal Spread of Crown Fires in a Dual-Layer Pinus koraiensis Canopy:Effects of Bulk Density and Canopy Gap Width Revealed through Controlled Ignition Experiments
摘要 树冠火是破坏性极强的森林火灾,但其在多冠层结构中的蔓延机制尚不明确.为此,以高火险的红松人工林为研究对象,在室内静风环境下,通过开展可控的双层冠树冠火点烧试验,揭示水平间距与冠层密度对双冠层树冠火蔓延行为与燃烧强度的耦合调控机制,以期为精细化火灾模型和防控策略提供理论依据.试验以2个冠层的密度与冠层间的水平间距为核心变量,均设置3个梯度.使用热电偶阵列和热流计同步测量冠层内部的温度场、热流密度及火焰前锋到达时间.所有工况均进行有效重复,并设置地表火蔓延与绝热对照组.研究结果表明,1)辐射传热是冠层间(无火焰直接接触)能量传递的主导机制,其热流占比稳定在40%~46%;2)系统存在明确的控制机制转换,火蔓延过程随间距减小出现从燃料控制向传热控制的机制转换;3)第二个冠层的引燃存在一个明确的温度阈值(250℃),且其前缘温度可作为有效的实时预测指标;4)第一个冠层的热流密度对系统整体火行为具有非线性强化作用,存在最佳配比与明确的过载临界值,超过临界值后减弱;5)在第一个冠层影响下,未引燃的第二个冠层二次点燃后温度有50%的频率显著超越自然蔓延的强度上限(最高超出105.63℃),实现燃烧性能提升.这表明树冠火受多因子影响的复杂性,任何旨在精准预测的模型都必须考虑冠层结构相互作用的非线性机制.
Abstract:
Crown fires are among the most destructive forest forms of wildland fire,however,their spread mechanisms within multi-layer canopy structures remain insufficiently understood.Therefore,this work focused on Pinus koraiensis plantation,characterized by high crow fire susceptibility.Through a series of controlled laboratory experiments,we in-vestigated the coupled regulatory effects of horizontal canopy spacing and canopy bulk density on crown fire spread behav-ior and burning intensity in a dual-layer canopy system,with the aim of providing a theoretical basis for refined fire mod-eling and prevention strategies.Experiments were conducted in a wind-free indoor environment,and the research was carried out through controlled dual-layer canopy crown fire burning experiments.The primary variables were the bulk density loads of two canopies and the horizontal spacing between canopy elements,each examined at three gradient lev-els.A thermocouple array and heat flux sensors were deployed to simultaneously measure internal temperature fields,ra-diant heat flux density,and flame front arrival times.All experimental conditions were fully replicated,with surface fire spread and adiabatic configurations included as control groups for comparison.Under calm wind and laboratory small-scale conditions,the research results indicated that:(1)radiant heat transfer was the dominant mechanism for energy transfer between canopies(without direct flame contact),and the proportion of heat flow remained stable at 40%-46%.(2)There was a clear control mechanism transition in the system.As the spacing decreased,the fire spread processed transitions from fuel control to heat transfer control mechanism.(3)There was a clear temperature threshold for the igni-tion of the second canopy(250℃),and the front edge temperature can serve as an effective real-time prediction indica-tor.(4)The heat flux density of the first canopy had a nonlinear reinforcing effect on the overall fire behavior of the sys-tem.There was an optimal ratio and a clear overload critical value,and it weakened after exceeding the critical value.(5)Under the influence of the first canopy,the reignited second canopy showed a 50%probability of its temperature sig-nificantly exceeding the intensity ceiling of natural spread(up to 105.63℃higher),achieving enhanced combustion performance.This illustrates hte complexity of crown fire as a multi factor systyem,indicating that any model aimed at precise prediction must take into account the nonlinear mechanisms of the interactions among the canopy structures.
刊 名 森林工程 ISTICPKU
年,卷(期): 2026, 42(5)
分类号: S762.1
机标分类号: S513 S715 X913
在线出版日期: 2026年9月17日
基金项目: 2022YFC3003002:国家重点研发计划ZZDYF250100002:黑龙江省重点研发计划项目,