摘要 首先,分析了单只电池参数差异、内阻变化、温度不一致等因素造成并联失衡的原因,以及对容量保持、循环寿命和运行安全的影响.其次,根据铅酸蓄电池的运行特性提出以电压偏差、电流分配、温升控制、荷电状态协调为依据的多参数融合均衡控制方法.最后,对参数采集、状态识别和控制流程实现进行设计.经由创建实验平台加以验证可知,该办法可有效抑制并联支路间的失衡扩展,改善电池组的一致性,提高容量利用率和运行稳定性.
Abstract:
This paper first analyzes the causes of parallel imbalance,including parameter differences among individual cells,variations in internal resistance,and inconsistent temperature,as well as their effects on capacity retention,cycle life,and operational safety.Based on the operational characteristics of lead-acid batteries,a multi-parameter fusion balancing control method is proposed,which is grounded in voltage deviation,current distribution,temperature rise control,and state of charge coordination.Subsequently,the design of parameter acquisition,state identification,and control process implementation is carried out.Through validation by constructing an experimental platform,it is demonstrated that this method effectively suppresses the propagation of imbalance among parallel branches,improves the consistency of the battery pack,and enhances capacity utilization and operational stability.
刊 名 蓄电池
年,卷(期): 2026, 63(5)
分类号: TM912.1
机标分类号: TM912 U284 U469.72
在线出版日期: 2026年9月30日