渣油加氢循环氢压缩机三级缸活塞杆断裂原因分析及对策
Analysis of the Causes and Solutions for Piston Rod Fracture in the Three-stage Cylinder of a Residual Oil Hydrogenation Circulation Compressor
摘要
以某石化企业渣油加氢循环氢压缩机为研究对象,对压缩机运行中突发三级缸活塞杆断裂故障,引发三级缸十字头滑履碎裂、中体滑道磨损,造成机组紧急停机事件进行分析.经停机前后参数对比、损坏部件现象、活塞杆断裂部分失效分析,确定此次压缩机故障的诱发原因及各部件损坏的机理,对损坏的部件按照损坏程度制定针对性的修复方案.根据故障发生的根本原因,提出了避免此类问题再次发生的维护措施及建议.
This paper takes the hydrogen recycle compressor for residue oil in a petrochemical company as the research object,analyzing an emergency shutdown caused by a sudden piston rod fracture in the third cylinder,which led to the breaking of the third cylinder crosshead slipper and wear on the central slideway.By comparing parameters before and after the shutdown,examining the damaged components,and analyzing the failed parts of the piston rod,the root cause of compressor failure and the damage mechanisms of each component were determined,and targeted repair plans were developed according to the extent of the damage.Based on the fundamental causes of the failure,maintenance measures and recommendations to prevent similar issues from happening again are proposed.
年,卷(期):
2026, (4)
分类号:
TH457
机标分类号:
R19
R473.73
TG157
在线出版日期:
2026年9月30日