军事知识服务平台
熔盐储热辅助煤电机组变负荷运行性能分析
Performance analysis of variable-load operation for coal-fired power units assisted by molten salt thermal energy storage
摘要 [目的]为提升燃煤机组在高比例新能源电网中的灵活调峰能力与能效水平,该文以 1 050 MW超超临界机组为研究对象,构建熔盐储热辅助变负荷运行的耦合系统模型.[方法]研究从储能与释能两个阶段展开,系统分析不同抽汽与回热节点配置对机组热经济性的影响,以确定合理的储释能路径.[结果]结果表明:主蒸汽乏汽汇入锅炉给水时循环效率最高,为50.1%;再热蒸汽乏汽汇入5号低压加热器出口时经济性最佳;给水泵出口取水回流至高压缸进口的释能方案综合性能最优,该方案实现调峰容量26.3 MW,循环效率50.54%,供电煤耗率253.17 g/kWh.[结论]该文可为燃煤机组的灵活性改造提供可行的技术路径与理论参考.
Abstract:
[Objective]To enhance the flexibility and energy efficiency of coal-fired units in high-renewable power grids,this study investigates a 1 050 MW ultra-supercritical unit coupled with a molten salt thermal energy storage system.[Methods]A system model covering both charging and discharging phases is established to analyze the effects of different steam extraction and feedwater heating configurations on thermal performance,aiming to identify an optimal energy storage and release strategy.[Results]Results show that mixing main steam exhaust into the boiler feedwater yields the highest cycle efficiency of 50.1%,while returning reheated steam exhaust to the fifth low-pressure heater outlet offers the best economy.The optimal discharging scheme—returning feedwater from the pump outlet to the high-pressure turbine inlet-achieves a peak-shaving capacity of 26.3 MW,cycle efficiency of 50.54%,and coal consumption rate of 253.17 g/kWh.[Conclusion]This study provides a feasible technical path and theoretical reference for flexibility retrofits of coal-fired units.
刊 名 中国测试 ISTICPKU
年,卷(期): 2026, 52(9)
分类号: TB9 TK26
机标分类号: TM773 TM621 TK323
在线出版日期: 2026年10月14日
基金项目: E2023502025:河北省自然科学基金BJ2025053:河北省高等学校科学研究项目,