摘要
[目的]建立人体尿液中 18种邻苯二甲酸单酯含量的高效液相色谱-串联质谱同时测定方法.[方法]试样经 β-葡萄糖苷酸酶/硫酸酯酶酶解,MAX小柱富集净化,Agilent RRHD SB-C18色谱柱(2.1 mm×100 mm,1.8 μm)分离,负离子多反应监测模式测定,内标法定量.[结果]方法线性范围良好,相关系数均≥0.999 8,检出限为0.03~1.50 ng/mL,定量限为 0.10~5.00 ng/mL,平均加标回收率为 82.10%~117.47%,相对标准偏差为 0.33%~9.87%,50 份人体尿样样本检测结果显示MMP、MECPP、MCMHP、MnBP、MEP、MEHHP、MEOHP、MiBP 等8种普遍检出,其检出率为 90%~100%.[结论]该方法具有简便、灵敏、准确、高效、经济等特点,可满足人体尿液中 18种邻苯二甲酸单酯含量的痕量测定需要.
[Objective]A simultaneous determination method for 18 phthalate monoesters in human urine was developed using HPLC-MS/MS.[Methods]The urine samples were enzymatically hydrolyzed with β-glucuronidase/sulfatase,purified and enriched using a MAX solid-phase extraction cartridge,and then separated on an Agilent RRHD SB-C18 column(100 mm×2.1 mm,1.8 μm).The analysis was performed in negative-ion multiple reaction monitoring(MRM)mode,and quantification was achieved by the internal standard method.[Results]The results demonstrated that the 18 phthalate monoesters showed good linear relationships,and all correlation coefficients were no less than 0.999 8.The method LODs were in the range of 0.03-1.50 ng/mL,and the LOQs were between 0.10 and 5.00 ng/mL.The average recoveries were between 82.10%and 117.47%,with relative standard deviations(RSDs)ranging from 0.33%to 9.87%.Eight phthalate monoesters including MMP,MECPP,MCMHP,MnBP,MEP,MEHHP,MEOHP and MiBP were widely detected in 50 human urine samples,with detection rates ranging from 90%to 100%.[Conclusion]This method is characterized as simple,sensitive,accurate,efficient and economical,which can meet the trace determination requirements of 18 phthalate monoesters in human urine.