新型CT定位法在肺癌患者颈内静脉入路输液港植入术中的应用效果
Clinical Efficacy of A Novel CT-based Localization Method for Totally Implantable Venous Access Port Placement in Lung Cancer via Internal Jugular Vein
摘要
背景与目的 输液港可显著降低肺癌化疗人群中静脉通路相关并发症的发生率,但其导管尖端精准置入上腔静脉-右心房交界处(cavoatrial junction,CAJ)仍是手术关键技术难点.目前,常用的心电图(electrocardiogram,ECG)引导定位法操作复杂、耗时较长.本研究基于临床实践,提出一种新型计算机断层扫描(computed tomography,CT)定位法,并科学评估该新型定位法的临床效能.方法 回顾性分析2024年1月至2026年4月于天津医科大学总医院肺部肿瘤外科行颈内静脉入路输液港植入的40例肺癌患者,根据定位方法分为CT定位组(n=20)与ECG定位组(n=20).通过术后CT测量导管尖端和CAJ距离,比较两组术后导管尖端位置的准确性和一致性,同时统计穿刺点和CAJ对应的体表解剖标志.结果 CT定位组定位精度更高、结果离散度更低(P=0.009);颈内静脉穿刺点对应的颈椎棘突水平以第7颈椎(C7)棘突最为常见,CAJ的体表投影在前胸壁和背部分别集中于第4肋-第4肋间隙和第7-8肋间隙.结论 新型CT定位法可显著提高颈内静脉内置管的准确率,优于传统ECG定位法,值得临床推广.
Background and objective Implantable venous ports can substantially reduce venous access-related complications in patients undergoing chemotherapy for lung cancer.However,accurate positioning of the catheter tip at the cavoatrial junction(CAJ),defined as the anatomical junction between the superior vena cava(SVC)and right atrium,remains technically challenging.Although electrocardiography(ECG)-guided positioning is widely used in clinical practice,the tech-nique can be relatively complex and time-consuming.Based on clinical practice,we developed a novel computed tomography(CT)-based positioning technique and aimed to evaluate its clinical efficacy and positioning accuracy.Methods We retrospec-tively analyzed 40 patients with lung cancer who underwent implantable port placement via the internal jugular vein at the Department of Lung Cancer Surgery,Tianjin Medical University General Hospital,between January 2024 and April 2026.The patients were divided into two groups according to the catheter tip positioning technique:the CT-guided positioning group(n=20)and the ECG-guided positioning group(n=20).Postoperative CT imaging was performed to measure the distance between the catheter tip and the CAJ.The accuracy and variability of catheter tip positioning were compared between the two groups.In addition,the surface anatomical landmarks corresponding to the internal jugular vein puncture site and the CAJ were recorded and analyzed.Results Compared with the ECG-guided group,the CT-guided group demonstrated significantly greater catheter tip positioning accuracy and lower positional variability(P=0.009).The seventh cervical spinous process(C7)was the most common surface anatomical landmark corresponding to the internal jugular vein puncture site.The surface pro-jection of the CAJ was predominantly located at the level of the 4th costal cartilage and the 4th intercostal space on the anterior chest wall and the 7th-8th costal cartilage level on the posterior thoracic wall.Conclusion The novel CT-based positioning technique demonstrated greater accuracy and consistency in catheter tip placement than ECG-guided positioning in patients undergoing internal jugular vein port implantation.
年,卷(期):
2026, 29(8)
机标分类号:
R77
R472
R654.2
在线出版日期:
2026年10月29日