Dynamic Stress Characteristics Analysis and Blade Damage Evaluation of Pump-Turbine Runner in Variable-Speed Units Under Pumping Mode
摘要
为探究转速和活动导叶联合调节的变负荷过渡过程对变速抽蓄机组转轮影响,基于单向流固耦合对某双馈式变速抽蓄机组抽水工况进行模拟,对比不同控制策略下转轮动力特性,并参考Park-Ang双参数损伤模型构建叶片损伤函数,进行叶片受损程度分析.控制策略分别为:交流励磁系统转速控制,机组调速器开度控制;交流励磁系统功率控制,机组调速器开度控制.结果表明:受外特性变化影响,转轮在转速-开度控制策略下最大等效应力及变形位移分别为167.73 MPa、0.727 49 mm,显著低于功率-开度控制策略最大等效应力279.9 MPa及最大变形位移1.848 5 mm;不同控制策略下,受主轴固定约束,应力无法通过变形释放,转轮应力最大值均位于叶片处,而位移分布则从外缘向主轴逐渐减小;基于构建的叶片损伤函数,发现叶片进水边与上冠连接处、叶片与下环连接处中部以及叶片出水边与上冠连接处损伤程度较高,且功率-开度控制策略下叶片最大损伤函数值为0.729 03,显著高于转速-开度控制策略下最大损伤值0.266 62,表明转轮在功率-开度控制策略下更容易发生损坏.
To investigate the influence of variable-load transition regulated jointly by rotational speed and guide-vane opening on the runner of a doubly-fed variable-speed pumped-storage unit,this study performed numerical simulations of the pumping mode under two existing control strategies of a hydropower station.A one-way fluid-structure interaction approach was adopted to compare the dynamic behavior of the runner under different strategies.A blade damage function was then constructed with reference to the Park-Ang two-parameter damage model to assess the degree of blade deterioration.The two control strategies were:① speed control via the AC excitation system combined with guide-vane opening control,and ② power control via the AC excitation system combined with guide-vane opening control.The results show that,influenced by variations in external characteristics,the maximum equivalent stress and deformation displacement of the runner under the speed-opening control strategy are 167.73 MPa and 0.727 49 mm,respectively,which are significantly lower than those under the power-opening control strategy(279.9 MPa and 1.848 5 mm).Under both strategies,the main shaft constraint prevented stress release through deformation,causing the maximum stress to occur in the blade region,while deformation decreased gradually from the outer rim toward the main shaft.Based on the constructed blade damage function,it is found that severe damage is more likely to occur at the junction between the blade leading edge and the upper crown,the mid-portion of the blade-lower ring connection,and the junction between the blade trailing edge and the upper crown.Moreover,the maximum damage index under the power-opening control strategy is 0.729 03,which is significantly higher than that under the speed-opening control strategy(0.266 62),indicating that the runner is more prone to damage under the power-opening control strategy.