Objective To investigate the changes and relevant factors of forward scatter after Epipolis laser in situ keratomileusis (Epi-LASIK)and laser in situ keratomileusis (LASIK). Methods It was a prospective clinical comparative study. 45 patients (45 eyes) were scheduled for Epi-LASIK and 42patients (42 eyes) for LASIK. Straylight examinations were performed using the C-Quant straylight meter before and 1,4, 10 months after surgery. The data was analyzed for statistical significance by one-way ANOVA and the correlation was tested by Pearson' s test by using SPSS 13. 0 software. Results The straylight values were(0. 91 ±0. 17) , (1. 03 ±0. 15) ,(1. 11 ±0. 13) , ( 1. 01 ±0. 16) of Epi-LASIK group and (0.96±0. 14) ,(1. 05 ±0. 12) ,(1. 10 ±0. 12) ,(0. 98 ±0. 15) of LASIK group preoperatively and 1,4,10 months postoperatively respectively,which there were significant increase postoperatively in both groups (F = 12.29,8.11;P<0.05). Compared with preoperative values, the changes in straylight values at 1, 4and 10 months postoperatively were (0. 12 ±0. 18) , (0. 19 ±0. 20) , (0. 08 ±0. 16) of Epi-LASIK group and (0.09 ± 0. 13 ) , ( 0. 15 ± 0. 17 ) , ( -0. 01 ± 0. 17 ) of LASIK group. In Epi-LASIK group, the preoperative refractive error, RBT/CCT, and ablation ratio have significant relevance with straylight values at 4 months postoperatively ( r = - 0. 344, - 0. 361 , 0. 361; P < 0. 05 ) , no such correlation was found in LASIK group (r = 0. 186,0. 162,-0.206;P>0. 05). For corneal haze which was found from 1 to4months after Epi-LASIK, grade 2, 1, 0. 5 appeared in 1, 2, 4 eyes respectively and the changes of straylight values were 0.52, (0.37, 0.42), (0.06, 0.09, 0.07, 0.17) at 4 months postoperatively. 10 months postoperatively, the increases of straylight values for the eye with grade 2 haze declined from 0. 52 to 0. 11after the haze disappeared. Conclusion Straylight values increase significantly at early time after EpiLASIK and LASIK, but decrease partially as time going. Corneal wound healing response may be the reasons induced the increases of light scatter after Epi-LASIK. For LASIK, flap interface factors may be the reasons.Corneal haze especially above mild grade, can affect the straylight obviously.